spacer left
 
Esmet Logo   Esmet Achitectural Product Photos
spacer
spacer
spacer
spacer
spacer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Esmet Home About Esmet Contact Esmet

Assemblies & Dimensions

Classic Turnbuckle with eye post assembly

1 Classic Turnbuckle with Eye Post Assembly
Part #
Rope Size
A
B
C
D
E
Take-Up
 
  CE-418-ST
3/16"
3/8"
1/2"
6-3/8"
1/4"-28
15/64"
2-1/8"
 
  CE-425-ST
1/4"
7/16"
5/8"
7-1/4"
5/16"-24
15/64"
2-1/8"
 

This tensioning fitting can be used for stairways and longer, straight runs of cable where take-up is required to obtain proper tension (see below). The turnbuckle will self-adjust for stairs or angled runs. An Eye Post Assembly is included.

Combine the classic turnbuckle with the following fittings based on the length of run:
0-25 feet: Combine with the Fixed Stud
26-75 feet: Combine with the Turnbuckle Stud
Over 75 feet: Combine with another Classic Turnbuckle

Fixed Eye with Threaded Tab Assembly

2 Fixed Eye with Threaded Tab Assembly
Part #
Rope Size
A
B
C
D
E
   
  CE-218-THD
3/16"
3/8"
1/2"
2-7/16"
1/4"-28
15/64"
   
  CE-225-THD
1/4"
7/16"
5/8"
3"
5/16"-24
15/64"
   

This non-tensioning fitting is used for stairways and angled runs. A Threaded Tab is included with this Eye Fitting Assembly.

Posts must be drilled and tapped to incorporate the threaded tab. This fitting can only be used when a minimum wall thickness of .250 is maintained. The hole must be drilled with an offset of 1/4" to maintain axial alignment for the threaded tab.

Fixed Eye with Threaded Tab Assembly

2A Fixed Eye with Eye Post Assembly
Part #
Rope Size
A
B
C
D
E
   
  CE-218-FT
3/16"
3/8"
1/2"
2-7/16"
1/4"-28
15/64"
   
  CE-225-FT
1/4"
7/16"
5/8"
3"
5/16"-24
15/64"
   

This non-tensioning fitting is used for stairways and angled runs. An Eye Post Assembly is included with this Eye Fitting Assembly. The hole must be drilled with an offset of 1/4" to maintain axial alignment for the fixed tab.

Fixed Eye with Threaded Tab Assembly

3 Turnbuckle Stud Assembly
Part #
Rope Size
A
B
C
Take-Up
     
  CE-418-ANG
3/16"
11/16"
1/2"
3-7/16"
1-1/2"
     
  CE-425-ANG
1/4"
13/16"
5/8"
3-13/16"
1-1/2"
     

This tensioning fitting is used for stairways with runs of moderate length. For a clean look, the fitting is assembled inside the post. For assemblies with wooden posts, fender washers are necessary. (See "Replacement Parts".)

Combine the classic turnbuckle with the following fittings based on the length of run:
0-25 feet: Combine with the Fixed Stud
26-75 feet: Combine with the Turnbuckle Stud
Over 75 feet: Combine with another Classic Turnbuckle

Turnbuckle Stud Assembly

4 Turnbuckle Stud Assembly
Part #
Rope Size
A
B
C
Take-Up
     
  CE-418
3/16"
11/16"
3-7/16"
7/16"
1-1/2"
     
  CE-425
1/4"
13/16"
3-13/16"
9/16"
1-1/2"
     

This tensioning fitting is used straight runs of moderate length. For a clean look, the fitting is assembled inside the post. For assemblies with wooden posts, fender washers are necessary. (See "Replacement Parts".)

Combine the classic turnbuckle with the following fittings based on the length of run:
0-25 feet: Combine with the Fixed Stud
26-75 feet: Combine with the Turnbuckle Stud
Over 75 feet: Combine with another Classic Turnbuckle

Fixed Stud Assembly

5 Fixed Stud Assembly
Part #
Rope Size
A
B
C
       
  CE-318
3/16"
11/16"
2-3/16"
7/16"
       
  CE-325
1/4"
13/16"
3"
9/16"
       

This non-tensioning fitting is used straight runs. For assemblies with wooden posts, fender washers are necessary. (See "Replacement Parts".)

Turnbuckle Stud Assembly

6 Classic Turnbuckle for Cement Posts
Part #
Rope Size
A
B
C
D
Take-Up
   
  CE-418-CEM
3/16"
5/8"
3-7/16"
1-1/2"
1/2"-13
2-1/8"
   
  CE-425-CEM
1/4"
7/8"
3-13/16"
1-1/2"
1/2"-13
2-1/8"
   

This tensioning fitting is used to obtain a more substantial architectural look or for longer, straight runs of cable where a lot of take-up is required for proper tension (see below). This fitting is threaded into cement posts with a drop-in anchor system.

Combine the classic turnbuckle with the following fittings based on the length of run:
0-25 feet: Combine with the Fixed Stud
26-75 feet: Combine with the Turnbuckle Stud
Over 75 feet: Combine with another Classic Turnbuckle

 

Electroline Architectural Fittings

spacer
spacer right

© Esmet, Inc. All rights reserved. | 1406 Fifth Street SW | Canton, Ohio 44702 USA | 330-452-9132 | Fax 330-452-2557 | Site Map | info@esmet.com